Initializing C2900XL flash...
flashfs[1]: 19 files, 2 directories
flashfs[1]: 0 orphaned files, 0 orphaned directories
flashfs[1]: Total bytes: 3612672
flashfs[1]: Bytes used: 3274240
flashfs[1]: Bytes available: 338432
flashfs[1]: flashfs fsck took 9 seconds.
flashfs[1]: Initialization complete.
...done Initializing C2900XL flash.
C2900XL POST: System Board Test: Passed
C2900XL POST: Daughter Card Test: Passed
C2900XL POST: CPU Buffer Test: Passed
C2900XL POST: CPU Notify RAM Test: Passed
C2900XL POST: CPU Interface Test: Passed
C2900XL POST: Testing Switch Core: Passed
C2900XL POST: Testing Buffer Table: Passed
C2900XL POST: Data Buffer Test: Passed
C2900XL POST: Configuring Switch Parameters: Passed
Failed data line test.
addr=0x80000, sent=0x00 recv=0x4000000
Del Mar Failure (2nd Del Mar): Failed Notify RAM POST
C2900XL POST FAILURE: Failed Notify RAM POST
C2900XL POST FAILURE: Ethernet Controller Test: Failed
C2900XL POST FAILURE: Failed Notify RAM POST
C2900XL POST FAILURE: MII Test: Failed
C2900XL POST FAILURE: Error waiting for Ethernet Controller and SW_PARAMS
C2900XL POST FAILURE: Initialization/POST failed
C2900XL POST FAILURE: AT: Failing because system POST failed
cisco WS-C2924M-XL (PowerPC403GA) processor (revision 0x11) with 8192K/1024K byt
es of memory.
Processor board ID FAB0611Y0TL, with hardware revision 0x03
Last reset from power-on
Processor is running Enterprise Edition Software
Cluster command switch capable
Cluster member switch capable
26 FastEthernet/IEEE 802.3 interface(s)
32K bytes of flash-simulated non-volatile configuration memory.
Base ethernet MAC Address: 00:09:43:85:88:C0
Motherboard assembly number: 73-3425-10
Power supply part number: 34-0920-01
Motherboard serial number: FAB061121R0
Power supply serial number: PHI0510017P
Model revision number: A0
Motherboard revision number: F0
Model number: WS-C2924M-XL-EN
System serial number: FAB0611Y0TL
Module Ports Model HW Version SW version
------ ----- ----- ---------- ----------
2 0 WS-X2922-XL-V xxxx xxxx
C2900XL INIT: Complete
FOUND an unknown transceiver on port 0
00:00:18: %LINK-4-ERROR: is experiencing errorsFOUND an unknown transceiver on
port 1
FOUND an unknown transceiver on port 2
FOUND an unknown transceiver on port 3
FOUND an unknown transceiver on port 4
FOUND an unknown transceiver on port 5
FOUND an unknown transceiver on port 6
FOUND an unknown transceiver on port 7
FOUND an unknown transceiver on port 9
FOUND an unknown transceiver on port 10
FOUND an unknown transceiver on port 11
FOUND an unknown transceiver on port 12
FOUND an unknown transceiver on port 13
FOUND an unknown transceiver on port 14
FOUND an unknown transceiver on port 15
FOUND an unknown transceiver on port 16
FOUND an unknown transceiver on port 18
FOUND an unknown transceiver on port 19
FOUND an unknown transceiver on port 20
FOUND an unknown transceiver on port 21
FOUND an unknown transceiver on port 22
FOUND an unknown transceiver on port 23
FOUND an unknown transceiver on port 24
FOUND an unknown transceiver on port 25
FOUND an unknown transceiver on port 30
FOUND an unknown transceiver on port 31
00:00:24: %SYS-5-RESTART: System restarted --
Cisco Internetwork Operating System Software
IOS (tm) C2900XL Software (C2900XL-C3H2S-M), Version 12.0(5)WC3b, RELEASE SOFTWA
RE (fc1)
Copyright (c) 1986-2002 by cisco Systems, Inc.
Compiled Fri 15-Feb-02 10:14 by antonino
--- System Configuration Dialog ---
At any point you may enter a question mark '?' for help.
Use ctrl-c to abort configuration dialog at any prompt.
Default settings are in square brackets '[]'
Cisco 2900XL Switch has a failed data line test during POST. How do I solve this problem?
Nice set up, but where do you put the batteries? Seriously, even if I had a clue what you were running (and I don't), aren't data line interruptions almost impossible to diagnose through an online forum? Why don't you ask the IT department. I bet that's what they get paid to do.
Reply:Replace this switch with a new Cisco 2960 or Cisco Express 500. Let me know if you need help.
James Kemery
Centricom Systems, Inc.
james.kemery@centricom.net Report It
Reply:How does the switch behave once it is up? I cannot find this message on CCO, and this is a very old switch, am I correct in guessing that it is not under any maintenance? You need TAC to debug that error, and I am not certain if you can even put that switch under SmartNet any longer.